Fujikin Incorporated: Space Rocket valves, nuclear valve, semiconductor valves, specialized valves, research and development of Fluid Dynamics, design, manufacturing sales and services.

  • Fujikin New Organization New Administration

About Fujikin

HOME > About Fujikin > Certifications/Qualifications > Classification of high-pressure gas certification > "3I 1C" Exemption Matrix:1

Classification of high-pressure gas certification

  • Certifications/Qualifications
  • Classification of high-pressure gas certification

Qualified Parts:"3I 1C" Exemption Matrix-1

What is "3I 1C"

3I: Hydrostatic Test (Inspection), Airtight Test (Inspection), Thickness Test (Inspection)
1C:Materials Regulation(Verification)

Prefectural governor (abbreviated as governor below) at the time of notification to the governor, or when conducted as "experimental" type and "approved" effect
Facility Manufacturing Facility(※1)
High Pressure Gas Facility(※2) Gas Facility (Low Pressure)(※3)
Safety Inspections and Notification on Finished Goods Hydrostatic test Required by the law -
Airtight test Required by the law 「法令」で特に規定はされていない
Thickness test Required by the law -
Materials Regulation Required by the law Required by the law
Technical Criteria Applicable Provision
  • No. 11,12,13,1, Paragraph 1, Article 6, of the General Law
  • No. 14,17,18,19, Paragraph 1, Article 6 of the Liquefied Petroleum Law
  • No. 16,17,18,19, Paragraph 1, Article 5 of the Combined Law
  • No. 14, Paragraph 1, Article 6 of the General Law
  • No. 14, Paragraph 1 of Article 6 of the Liquefied Petroleum Law
  • No. 16, Paragraph 1, Article 5 Combined Law
Criteria for Required Notifications, Inspections and Authorizations Notification Required
  • Manufacturer Type 2 (Section 2 of Article 5 of the Act)
-
"Manufacturing license" and "completion inspection", "safety inspection" is required
  • Manufacturer of the first kind (see Section 1 of Article 5 of the Act)
  • Completion test (Article 20 of the Act)
  • Safety inspection (Article 35 of the Act)
-
※1
Manufacturing Facility.
※2
High Pressure Gas Facilities: Passage of High Pressure Gas within Gas Facility.
※3
Gas Facilities: Passage of High Pressure Gas or Liquefied Petroleum Gas when High Pressure Gas is produced.
[Definitions (Article 2 of the General Law), (Article 2 of the Supplementary Liquefied Petroleum Law) (Article 2 of the Combined Law)]

Legend

Required by the law
     Required by Law
「法令」で特に規定はされていない
     Although not required by law, implementation is necessary from the quality control aspect.

Effects of Certified Product

Certified product has cleared the standards and criteria, resulting in:

  1. Exemption from completion test, safety test and various tests.
  2. Raised quality management standards.

By utilizing Certified Product where marked Required by the law will result in benefits marked (1)(2).